Applications: This model is used for measuring salinity of solution such as sea water,physiological saline solution and refractive index of measured solution .Feature: Measuring Range:0 to 10% salinity; 1.3330 to 1.3903 Nd Accuracy: +/-0.1% salinity; +/-0.00015 Nd Operation temperature :0°C to 40°C (32°F to 104°F) Temperature Measurement Range:0 to 40°C(32 to 104°F) Power supply :1 battery (9V) Alarm of low voltage Automatic temperature compensation Automatic shut off
Specification:
Product Model Parameter Test Code Measuring Range Resolution Accuracy ATC Brix RHD-101 Brix S01 0.0-50.0% 0.10% +/-0.2% Yes Refractive Index S02 1.3330-1.4200nD 0.0001nD +/-0.0003nD Yes RHD-102 Brix S01 0.0-90.0% 0.10% +/-0.2% Yes Refractive Index S02 1.3330-1.5177nD 0.0001nD +/-0.0003nD Yes RHD-103 Dextran S01 0.0-10.6% 0.10% +/-0.2% Yes Fructose S02 0.0-68.9% 0.10% +/-0.2% Yes Glucose S03 0.0-59.9% 0.10% +/-0.2% Yes Lactose S04 0.0-16.5% 0.10% +/-0.2% Yes Maltose S05 0.0-15.60% 0.10% +/-0.2% Yes Refractive Index S06 1.3330-1.4200nD 0.0001nD +/-0.0003nD Yes Salinity RHD-201 (Sodium Chloride NaCl)
salinity S01 0.0-28.0% 0.10% +/-0.2% Yes salinity S02 0-280‰ 1‰ +/-2‰ Yes specific gravity S03 1.000-1.217 0.001 +/-0.002 Yes Refractive Index S04 1.3330-1.3900nD 0.0001nD +/-0.0003nD Yes RHD-202(Sea Water) salinity S01 0-100‰ 1‰ +/-2‰ Yes chlorinity S02 0-57‰ 1‰ +/-2‰ Yes specific gravity S03 1.000-1.070 0.001 +/-0.002 Yes Refractive Index S04 1.3330-1.3530nD 0.0001nD +/-0.0003nD Yes Honey RHD-301 Brix S01 0.0-90.0% 0.10% +/-0.2% Yes Water S02 38.0%-5.0% 0.10% +/-0.2% Yes Be' S03 33.0-48.0 0.1 +/-0.2% Yes Refractive Index S04 1.3330-1.5177nD 0.0001nD +/-0.0003nD Yes Grape Wine
OE Beverage
RHD-401
Brix%
S01
0.0-45.0%
0.10%
+/-0.2%
Yes
%VOL ap
S02
0.0-22.0%
0.10%
+/-0.2%
Yes
Oe
S03
3-150
1
+/-2%
Yes
KMW
S04
0.0-25.0
0.1
+/-0.2
Yes
Beer Brix Wort S.G.
RHD402
Brix
S01
0.0-50.0%
0.1%
+/-0.2
Yes
Wort S.G.
S02
1.000-1.030
0.001S.G.
+/-0.002
Yes
Clinical Protein/Urine
RHD-501
Urine S.G.
S01
1.000-1.050
0.001
+/-0.002
Yes
Serum Protein.
S02
0-12
0.1
+/-0.2
Yes
Refractive Index
S03
1.3330-1.3900nD
0.0001nD
+/-0.0003nD
Yes
Car RHD-601 Antifreeze Freezing Point
Cleaner S01 0~(-40)°C 0.1°C +/-0.5°C Yes Ethylene Glycol S02 0~(-50)°C 0.1°C +/-0.5°C Yes Propylene Glycol S03 0~(-50)°C 0.1°C +/-0.5°C Yes Battery Fluid S04 1.000-1.500sg 0.001 +/-0.005sg Yes RHD-602 (Car Urea Concentration) Urea (NH2)2C0 S01 0-51.0% 0.1% +/-0.2% Yes Refractive Index S02 1.3330-1.4056nD 0.0001nD +/-0.0003nD Yes RHD-603 Coolant Freezing Point and Concentration Ethylene Glycol (v/v) S01 0-60% 0.10% +/-0.5% Yes Ethylene Glycol (°C) S02 0~(-50)°C 0.1°C +/-0.5°C Yes Propylene Glycol (v/v) S03 0-70% 0.10% +/-0.5% Yes Propylene Glycol (°C) S04 0~(-60)°C 0.1°C +/-0.5°C Yes RHD-604 Brake Fluid Boiling Point