Power Factor Power Clamp Meter True RMS

FOB Reference Price:Get Latest Price
1 Piece/Pieces (Min. Order)
Shipping:
Support Sea freight
Report Suspicious Activity
Overview
Quick Details
Place of Origin:
Taiwan, China
Brand Name:
TES
Model Number:
PROVA-6601
Display Type:
Digital Only
Measuring Energy Range:
1200KW
Accuracy Class:
2%
Output Voltage:
800V
Operating Temperature:
0 °C to 50 °C
Dimensions:
271mm(L)*112mm(W)*46mm(H)
Supply Ability
Supply Ability:
3000 Piece/Pieces per Month
Packaging & Delivery
Packaging Details
Carrying Case
Port
Shanghai
Lead Time :
3-10 working days after we receivedwn payment

Features:

PF( 3 Φ 3W , 3 Φ 4W 1Φ 2W ) 
AC+DC 2000A,600V Power Factot 
AC+DC 1200KW(1 Φ ) AC+DC 200KW(3Φ ) 
AC/DC Auto Detection 
Dual Display V+Hz, A+V,KW+PF,KVA+KVAR 

Specifications:

AC+DC True Power (Power Factor 0.2 ~ 1.0,3 Φ 3W , 3 Φ 4W 1Φ 2W and, 1 Φ 3W)

Range

Resolution

Accuracy (of rdg)

Input Range

0~99.9KW

0.01KW

+/-2.0%+/-0.05KW

AC600V,DC800V

ACA/DCA2000A

100~999.9KW

0.1KW

+/-2.0%+/-0.5KW

AC600V,DC800V

ACA/DCA2000A

1000~1200KW

1KW

+/-2.0%+/-5KW

AC600V,DC800V

ACA/DCA2000A

AC+DC Voltage (True RMS ,Crest Factor < 4 ,Autorange, Overload Protection 800VAC for all range )

Range

Resolution

Accuracy( of reading)

Input Range

 

 

DC,50/60

Hz 40~400Hz

 

0~200V

0.1V

+/-1.5%+/-5dgts

+/-2.0%+/-5dgts

10M Ω

200~500V

0.1V

+/-1.5%+/-5dgts

+/-2.0%+/-5dgts

10M Ω

500~600VAC 500~800V

1V

+/-1.5%+/-5dgts

+/-2.0%+/-5dgts

10M Ω

AC+DC A (True RMS, Crest Factor < 4)

Range

Resolution

Accuracy( of reading)

Overload Protection

 

 

DC,50/60

Hz 40~400Hz

 

0~200A

0.1A

+/-1.5%+/-5dgts

+/-2.0%+/-5dgts

AC 3000A

200~500A

0.1A

+/-2.5%+/-5dgts

+/-2.5%+/-5dgts

AC 3000A

500~2000A

1A

+/-2.5%+/-5dgts

+/-3.0%+/-5dgts

AC 3000A

AC+DC KVAR (3 Φ 3W, 3 Φ 4W)

Range

Resolution

Accuracy (of rdg)

Input Range

0~99.9KW

0.01KW

+/-2.0%+/-0.05KVAR+/-3°

AC600V,DC800V ACA/DCA2000A

100~999.9KW

0.1KW

+/-2.0%+/-0.5KVAR+/-3 °

AC600V,DC800V ACA/DCA2000A

1000~1200KW

1KW

+/-2.0%+/-5KVAR+/-3 °

AC600V,DC800V ACA/DCA2000A

Frequency(Hz) (if < 10 Hz , Hz = 0)

Range

Accuracy

Sensitvity

50/60Hz

+/-2dgts

V>1V,A>5A

10~400Hz

+/-0.5%+/-2dgts

V>1V,A>5A

General Specification

Conductor Size

Cable F 55mm (appro*) Bus Bar 65mm(D) * 24mm(W)

Battery Type

9V

Display

2 * 4 Digits Dual Display LCD

Range Selection

Auto

Power Consumption

Overload Indication

OL

Sampling TIME

5sec (V and A) 16sec(W)

Operating Temperature

4 °C ~ 50 °C

Operating Humidity

Less than 80% relative

Storage Temperature

-20 °C ~ 60 °C (-40 °F ~140 °F )

Storage Humidity

Less than 75% relative

Power Consumption

About 25mA

Dimension

10.7"(L) * 4.4"(W) * 18"(H) 271mm(L) * 112mm(W) * 26.2mm(H)

Weight

647g / 22.8oz. (Batteries Included)

Accessories

Carrying bag * 1 Users manual * 1 9V Battery * 1 (Installed)